CCT-95-0/2K_CCT-95-0/20K_CCT-95-0/200K信號(hào)調(diào)節(jié)器OMEGA
價(jià) 格:詢價(jià)
產(chǎn) 地:美國更新時(shí)間:2020-09-22 10:11
品 牌:歐米茄型 號(hào):CCT-95-0/2K
狀 態(tài):正常點(diǎn)擊量:1372
上海非利加實(shí)業(yè)有限公司
聯(lián) 系 人: 上海非利加實(shí)業(yè)有限公司
電 話: 400-006-7520
傳 真: 400-006-7520
配送方式: 上海自提或三方快遞
聯(lián)系我時(shí)請(qǐng)說在上海非利加實(shí)業(yè)有限公司上看到的,謝謝!
CCT-95-0/2K_CCT-95-0/20K_CCT-95-0/200K信號(hào)調(diào)節(jié)器OMEGA
CCT系列DIN軌道信號(hào)調(diào)節(jié)器設(shè)計(jì)用于接收廣泛的輸入信號(hào),如交流和直流電壓和電流、頻率、溫度(熱電偶和RTD)和過程傳感器,并提供0/4至20 mA或0至10 Vdc的標(biāo)準(zhǔn)過程輸出。CCT系列采用現(xiàn)代外殼設(shè)計(jì),易于安裝在標(biāo)準(zhǔn)DIN導(dǎo)軌上。連接安全可靠,輸入和輸出連接在模塊的另***側(cè)。
內(nèi)部設(shè)計(jì)
CCT系列采用內(nèi)部插件三模塊系統(tǒng)設(shè)計(jì),可靈活選擇和更改電源、輸入信號(hào)和輸出信號(hào)。該裝置提供110伏交流電標(biāo)準(zhǔn)電源,220伏交流電和24伏直流電請(qǐng)咨詢銷售。
產(chǎn)品參數(shù)
CCT-95-0/2K_CCT-95-0/20K_CCT-95-0/200K信號(hào)調(diào)節(jié)器OMEGA
電源:110 Vac(標(biāo)準(zhǔn));220 Vac或24 Vdc(可選)(所有電源的公差為±10%)
輸出:4至20 mA和0至10 Vdc標(biāo)準(zhǔn);通過跳線選擇0至20 mA
精度:≤0.2%或≤0.3,%,取決于型號(hào)
應(yīng)時(shí)間:≤250 ms
隔離:2 kVeff
紋波:≤0.5%
帶通:1.5赫茲(-3分貝)
工作環(huán)境:-10至60°C(14至140°F)
儲(chǔ)存環(huán)境:-30至80°C(-22至176°F)
溫度系數(shù):≤0.015%/°C
功:最大1.5 VA
外殼:聚碳酸酯,RAL 7032;UL 94 V-1,IP40保護(hù)
端子外殼:聚碳酸酯,UL 94-2,IP20保護(hù)
最大線徑:4 mm2(14 AWG)
尺寸:75 H x 45 W x 110 mm D(2.95“x 1.77”x 4.33“)
重量:270克(0.6磅)
安裝:DIN軌道46277和EN 50022(35 x 7.5 mm)
產(chǎn)品介紹
CCT-95-0/2K_CCT-95-0/20K_CCT-95-0/200K信號(hào)調(diào)節(jié)器OMEGA
Voltage, Current, Frequency, Resistance, Potentiometer, Thermocouple, RTD and Strain Gage Input Modules
Integrator Modules Convert Voltage or Current to Frequency
Loop Powered Galvanic Isolator Provides 2 kVeff Isolation Between Input and Output
Compatible with Standard 35 mm DIN Rail
The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module.
Internal Design
The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. The units are supplied with 110 Vac power standard, Consult sales for 220 Vac, and 24 Vdc power.
Isolation
The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff.
Outputs
Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc.
Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.
pecifications
Power: 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies)
Output: 4 to 20 mA and 0 to 10 Vdc standard; 0 to 20 mA via jumper select
Accuracy: ≤0.2% or ≤0.3,%, depending on the model
Response Time: ≤250 ms
Isolation: 2 kVeff
Ripple: ≤0.5%
Bandpass: 1.5 Hz (-3 dB)
Operating Ambient: -10 to 60°C (14 to 140°F)
Storage Ambient: -30 to 80°C (-22 to 176°F)
Temperature Coefficient: ≤0.015%/°C
Power Consumption: 1.5 VA max
Enclosure: Polycarbonate, RAL 7032; UL 94 V-1, IP40 protection
Terminal Housing: Polycarbonate, UL 94-2, IP20 protection
Max Wire Size: 4 mm2 (14 AWG)
Dimensions: 75 H x 45 W x 110 mm D (2.95" x 1.77" x 4.33")
Weight: 270 g (0.6 lb)
Mounting: DIN rail 46277 and EN 50022 (35 x 7.5 mm)